Umzekelo | I-KL-8052N |
Inkqubo yokumpompa | I-Curvilinear peristaltic |
Iseti ye-IV | Iyahambelana neeseti ze-IV zawo nawuphi na umgangatho |
Umgangatho wohambo | I-0.1-1500 ml / h (kwi-0.1 ml / i-increments) |
Hlanza, Bolus | 100-1500 ml/h (kwi-1 ml/h increments) Hlanza xa impompo iyeka, i-bolus xa impompo iqala |
Umthamo weBolus | 1-20 ml (kwi-1 ml yonyuso) |
Ukuchaneka | ±3% |
*I-Thermostat eyakhelweyo | 30-45 ℃, iyahlengahlengiswa |
VTBI | 1-9999 ml |
Imo Yokugalela | ml/h, drop/min, usekwe kwixesha |
Ixabiso le-KVO | 0.1-5 ml/h (kwi-0.1 ml/h increments) |
Iialamu | Ukuvalela, ukungena emoyeni, ukuvula umnyango, inkqubo yokuphela, ibhetri ephantsi, ibhetri yokuphela, Ukucima kombane we-AC, ukungasebenzi kakuhle kwemoto, ukungasebenzi kakuhle kwenkqubo, ukulinda |
Iimpawu ezongezelelweyo | Ixesha lokwenyani lokufakwa kwevolumu / inqanaba le-bolus / ivolumu ye-bolus / ireyithi ye-KVO, Ukutshintsha amandla okuzenzekelayo, isitshixo sisimumu, ukucoca, i-bolus, imemori yenkqubo, isitshixo esitshixo, tshintsha izinga lokuhamba ngaphandle kokumisa impompo |
Uvakalelo lokuvalelwa | Iphezulu, iphakathi, iphantsi |
Ukufunyanwa kwe-Air-in-line | Umtshina we-ultrasonic |
WirelessMulawulo | Ukhetho |
Ubonelelo lwaMandla, AC | 110/230 V (ukhetho), 50-60 Hz, 20 VA |
Ibhetri | 9.6±1.6 V, iyatshajwa kwakhona |
Ubomi Bebhetri | Iiyure ezi-5 kwi-30 ml / h |
Ubushushu bokusebenza | 10-40℃ |
Ubuntu bezizalwane | 30-75% |
Uxinzelelo lwe-Atmospheric | 700-1060 hpa |
Ubungakanani | 174*126*215 mm |
Ubunzima | 2.5 kg |
Ulwahlulo loKhuseleko | Udidi Ⅰ, uhlobo CF |
Iimbonakalo:
1. I-thermostat eyakhelwe ngaphakathi: 30-45℃ elungelelanisiweyo. Lo matshini ufudumeza ityhubhu ye-IV ukwandisa ukuchaneka kwe-infusion.
Eli lilungu elikhethekileyo xa lithelekiswa nezinye iiMpompo zokuPhunxa.
2. Ubuchwephesha obuphezulu bokuchaneka okuphezulu kunye nokuhambelana.
3. Isebenza kubantu abadala, iZinyanga zabantwana kunye neNICU (iNeonatal).
4. Umsebenzi we-Anti-free-flow ukwenza infusion ikhuseleke.
5. Umboniso wexesha langempela lomthamo ofakiweyo / umlinganiselo we-bolus / umthamo we-bolus / izinga le-KVO.
6, Isiboniso esikhulu se-LCD. Okubonakalayo kwiscreen ii-alam ezili-9.
7. Guqula izinga lokuhamba ngaphandle kokumisa impompo.
8. Ii-CPU ezimbini zokwenza inkqubo yokugalela ikhuseleke.
9. Ukuya kuthi ga kwiiyure ezi-5 zokugcina ibhetri, isalathisi sesimo sebhetri.
10. Kulula ukusebenzisa ifilosofi yokusebenza.