Ipompo yeSiringe ye-KL-6061N: I-High-Precision (± 2%) i-Multi-Syringe Compatibility (5-60ml), Iindlela eziNxulumeneyo zokuNgeniswa, Iimpawu zoKhuseleko oluPhezulu, ukhetho olungenacingo, kunye ne-10-Hour ye-Battery Life for Clinical Efficiency
KellyMed Impompo yesiringe I-KL-6061N indawo yokusebenzela
,



Impompo yesirinji ye-KL-6061N
Iinkcukacha
| Ubungakanani besirinji | 5,10, 20, 30, 50/60 ml |
| Isirinji esebenzayo | Iyahambelana nesirinji yawo nawuphi na umgangatho |
| Umgangatho wohambo | Isirinji 5 ml: 0.1-100 ml/hIsirinji 10 ml: 0.1-300 ml/hIsirinji 20 ml: 0.1-600 ml/hIsirinji 30 ml: 0.1-800 ml/hIsirinji 50/60 ml: 0-1-9 ml/h. I-0.01 ml/h increments100-999.9 ml/h kwi-0.1 ml/h increments1000-1500 ml/h kwi-1 ml/h increments |
| Flow Rate Ukuchaneka | ±2% |
| VTBI | 0.10mL~99999.99mL (Ubuncinane ku-0.01 ml/h ukunyuswa) |
| Ukuchaneka | ±2% |
| Ixesha | 00:00:01~99:59:59(h:m:s) (Ubuncinane kwi-1s ukunyuswa) |
| Izinga lokuHamba (ubunzima bomzimba) | 0.01~9999.99 ml/h ;(nge-0.01 ml yonyuso) iyunithi: ng/kg/min,ng/kg/h,ug/kg/min,ug/kg/h,mg/kg/min,mg/kg/h,IU/kg/min,IU/kg/h,EU/kg/min,EU/ |
| Ixabiso leBolus | Isirinji 5 ml: 50mL/h-100.0 mL/hIsirinji 10 ml: 50mL/h-300.0 mL/hSrinji 20 ml: 50mL/h-600.0 mL/hSringe 30 ml: 50mL/h-60 ml/h-800. 50mL/h-1500.0 mL/h50-99.99 mL/h, kwi-0.01 ml/h increments100-999.9 ml/h kwi-0.1 ml/h increments1000-1500 ml/h kwi-1 ml/h incrementsAccuray: ±2% |
| Umthamo weBolus | Isirinji 5 ml: 0.1mL-5.0 mLSsirinji 10 ml: 0.1mL-10.0 mLSsirinji 20 ml: 0.1mL-20.0 mLSsirinji 30 ml: 0.1mL-30.0 mLSsirinji 50/60 ml-60mLA: 0.0mLA60mLA: 0.1mLA: 0.1mLA: 0.1mLA ±2% okanye ±0.2mL |
| Bolus, Hlanza | Isirinji 5mL: 50mL/h -100.0 mL/hSringe 10mL: 50mL/h -300.0 mL/hSrinji 20mL: 50 mL/h-600.0 mL/hSrinji 30mL0/h5. mL/hSyringe 50mL:50 mL/h -1500.0 mL/h(Ubuncinane kwi-1mL/h increments) Ukuchaneka: ±2% |
| Uvakalelo lokuvalelwa | 20kPa-130kPa, ehlengahlengiswayo (kwi-10 kPa yonyuso) Ukuchaneka: ±15 kPa okanye ±15% |
| Ixabiso le-KVO | 1).Automatic KVO On/Off Function2).I-KVO ezenzekelayo icinyiwe : Ireyithi ye-KVO : 0.1~10.0 mL/h adjustable,(Ubuncinane kwi-0.1mL/h ukunyuswa).Xa isantya sokuhamba>Ireyithi ye-KVO , isebenza ngereyithi ye-KVO.Xa isantya sokuhamba |
| Umsebenzi osisiseko | Ukujongwa koxinzelelo lwe-Dynamic, i-Anti-Bolus, i-Key Locker, i-Standby, imemori yeMbali, ilayibrari yeziyobisi. |
| Iialamu | Ukuvalela, ukwehla kwesirinji, ukuvulwa kocango, kufutshane nesiphelo, inkqubo yokuphela, ibhetri ephantsi, ibhetri yokuphela, ukungasebenzi kakuhle kwemoto, ukungasebenzi kakuhle kwenkqubo, ialam yokulinda, impazamo yokufaka isirinji |
| Imo Yokugalela | Imowudi yokukala, imo yexesha, ubunzima bomzimba, iMowudi yolandelelwano, iMowudi yedosi, iMowudi yeRamp Phezulu/ezantsi, iMowudi yeInfu encinci |
| Iimpawu ezongezelelweyo | Ukuzijonga, iMemori yeNkqubo, i-Wireless (ukhetho), i-Cascade, i-Battery Missing Prompt, i-AC Power Off Prompt. |
| Ukufunyanwa kwe-Air-in-line | Umtshina we-ultrasonic |
| Ubonelelo lwaMandla, AC | AC100V~240V 50/60Hz, 35 VA |
| Ibhetri | 14.4 V, 2200mAh, Lithium, etshajwayo |
| Ubunzima bebhetri | 210g |
| Ubomi Bebhetri | Iiyure ezili-10 kwi-5 ml / h |
| Ubushushu bokusebenza | 5℃~40℃ |
| Ubuntu bezizalwane | 15%~80% |
| Uxinzelelo lwe-Atmospheric | 86KPa~106KPa |
| Ubungakanani | 290×84×175mm |
| Ubunzima | <2.5 kg |
| Ulwahlulo loKhuseleko | Udidi ⅠI, chwetheza CF. IPX3 |






FAQ:
Umbuzo:Yintoni i-MOQ yale modeli?
A: iyunithi e-1.
Umbuzo: Ngaba i-OEM yamkelekile? kwaye yintoni i-MOQ ye-OEM?
A: Ewe, sinokwenza iOEM ngokusekelwe kwiiyunithi ezingama-30.
Umbuzo: Ngaba ungumvelisi wale mveliso.
A: Ewe, ukusukela ngo-1994
Umbuzo: Ngaba unaso izatifikethi ze-CE kunye ne-ISO?
A: Ewe . zonke iimveliso zethu CE kunye ISO eqinisekisiweyo
Umbuzo: Yintoni iwaranti?
A: Sinika iwaranti yeminyaka emibini.
Umbuzo: Ngaba le modeli iyasebenza kunye nesikhululo seDocking?
A: Ewe

Iimbonakalo :
➢ Uyilo olubambeneyo, olukhaphukhaphu, kunye nombhalo omncinci wokuphatheka lula.
➢ Ujongano lomsebenzisi olusebenziseka lula olulula noluqondakalayo.
➢ Ingxolo ephantsi yokusebenza kwindawo ezolileyo.
➢ Iindlela ezisithoba zokusebenza ukuhlangabezana neemfuno ezahlukeneyo zonyango.
➢ Idatha efakelwe kwangaphambili yeebrand ezintathu zesirinji ukulungiselela ukhetho olufanelekileyo lwesirinji.
➢ Inketho enokwenziwa ngokwezifiso ukufaka iinkcukacha kwiisirinji ezimbini ezongezelelweyo.
➢ Umsebenzi we-Anti-Bolus ukunqanda ukufakwa ngokugqithisileyo.
➢ Izivusi ezivakalayo nezibonwayo zokhuseleko oluphuculweyo lwezigulane.
➢ Ukuboniswa ngaxeshanye kwedatha ebalulekileyo yeklinikhi yokujongwa ngokukhawuleza.
➢ Utshintsho oluzenzekelayo kwimowudi ye-KVO (Keep Vein Open) ekugqityweni kokufakwa kweVTBI.